Namely splitting the handles for each in 2 separate tables and adding
a `.cancel_service_task()`.
Also,
- move `_open_and_supervise_service_ctx()` to mod level.
- rename `target` -> `ctx_fn` params througout.
- fill out method doc strings.
Namely distinguishing service "IPC contexts" (opened in a
subactor via a `Portal`) from just local `trio.Task`s started
and managed under the `.service_n` (more or less wrapping in the
interface of a "task-manager" style nursery - aka a one-cancels-one
supervision start).
API changes from original (`piker`) impl,
- mk `.start_service_task()` do ONLY that, start a task with a wrapping
cancel-scope and completion event.
|_ ideally this gets factored-out/re-implemented using the
task-manager/OCO-style-nursery from GH #363.
- change what was the impl of `.start_service_task()` to `.start_service_ctx()`
since it more explicitly defines the functionality of entering
`Portal.open_context()` with a wrapping cs and completion event inside
a bg task (which syncs the ctx's lifetime with termination of the
remote actor runtime).
- factor out what was a `.start_service_ctx()` closure to a new
`_open_and_supervise_service_ctx()` mod-func holding the meat of
the supervision logic.
`ServiceMngr` API brief,
- use `open_service_mngr()` and `get_service_mngr()` to acquire the
actor-global singleton.
- `ServiceMngr.start_service()` and `.cancel_service()` which allow for
straight forward mgmt of "service subactor daemons".
In the `examples/debugging/restore_builtin_breakpoint.py` i had put the
pattern-comment lines on the line following the `breakpoint()` bc it
seems that's where `pdb` would always "stop" and print the line to
console? So the test would only pass by actually ensuring that in the
`pexpect` capture..
Now on 3.13 it seems that the `pdb` line halting must have been fixed;
it now renders to console the same `breakpoint()` line?
Anyway it works as you'd expect now but **only** on 3.13 so after this
change we might have to adjust the tests to `pytest.xfail()` on earlier
versions.
Like any `bdb.BdbQuit` that might be relayed from a remote context after
a REPl exit with the `quit` cmd. This fixes various issues while
debugging where it may not be clear to the parent task that the child
was terminated with a purposefully unrecoverable error.
Inside a new `.trionics._beg` and exposed from the subpkg ns in
anticipation of the `strict_exception_groups=False` being removed by
`trio` in py 3.15.
Notes,
- mk an embedded single-exc "extractor" using a `BaseExceptionGroup.exceptions` length
check, when 1 return the lone child.
- use the above in a new `@acm`, async bc it's most likely to be composed in an
`async with` tuple-style sequence block, called `collapse_eg()` which
acts a one line "absorber" for when the above mentioned flag is no
logner supported by `trio.open_nursery()`.
All untested atm fwiw.. but soon to be used in our test suite(s) likely!
Including changes like,
- loose eg flagging in various test emedded `trio.open_nursery()`s.
- changes to eg handling (like using `except*`).
- added `debug_mode` integration to tests that needed some REPLin
in order to figure out appropriate updates.
Namely when the subactor fails to lock the root, in which case we
try to be very verbose about how/what failed in logging as well
as ensure we cancel the employed IPC ctx.
Implement the outer `BaseException` handler to handle both styles,
- match on an eg (or the prior std cancel excs) only raising a lone
sub-exc from for former.
- always `as _req_err:` and assign to a new func-global `req_err`
to enable the above matching.
Other,
- raise `DebugStateError` on `status.subactor_uid != actor_uid`.
- fix a `_repl_fail_report` ref error due to making silly assumptions
about the `_repl_fail_msg` global; now copy from global as default.
- various log-fmt and logic expression styling tweaks.
- ignore `trio.Cancelled` by default in `open_crash_handler()`.
Namely inside,
- `ActorNursery.open_portal()` which uses
`.trionics.maybe_open_nursery()` and is now adjusted to
pass-through `**kwargs` for at least this flag.
- inside the `.trionics.gather_contexts()`.
Such that it gets passed through to `.open_root_actor()` in the
`implicit_runtime==True` case - useful for debugging cases where
`.devx._debug` APIs might be used to avoid REPL clobbering in subactors.
Since it'll likely need a bit of detailing to get the test suite running
identically with strict egs (exception groups), i've opted to just flip
the switch on a few core nursery scopes for now until as such a time
i can focus enough to port the matching internals.. Xp
Since it turns out there's a few gotchas moving to python 3.13,
- we need to pin to new(er) `trio` which now flips to strict exception
groups (something to be handled in a follow up patch).
- since we're now using `uv` we should (at least for now) prefer the
system `python` (over astral's distis) since they compile for
`libedit` in terms of what the (new) `readline.backend: str` will read
as; this will break our tab-completion and vi-mode settings in
the `pdbp` REPL without a user configuring a `~/.editrc`
appropriately.
- go back to using latest `pdbp` (not a local dev version) since it
should work fine presuming the previous bullet is addressed.
Lock bumps,
- for now use latest `trio==0.29.0` (which i gotta feeling might have
broken some existing attempts at strict-eg handling i've tried..)
- update to latest `xonsh`, `pdbp` and its dep `tabcompleter`
Other cleaning,
- put back in various deps "comments" from `poetry` content.
- drop the `xonsh-vox` and `xontrib-vox` dev deps; no `vox` support with
`uv` rn anyway..
Such that a `TrioCancelled` is raised in the aio task via
`.set_exception()` to explicitly indicate and allow that task to handle
a taskc request from the parent `trio.Task`.
Namely the `tractor.pause_from_sync()` examples using both bg threads
and `asyncio` which seem to go into bad states where SIGINT is ignored..
Deats,
- add `maybe_expect_timeout()` cm to ensure the EOF hangs get
`.xfail()`ed instead.
- @pytest.mark.ctlcs_bish` `test_pause_from_sync` and don't expect the
greenback prompt msg.
- also mark `test_sync_pause_from_aio_task`.
Seems that on 3.13 it's not showing our script code in the output now?
Gotta get an example for @oremanj to see what's up but really it'd be
nice to just custom format stuff above `trio`'s runtime by def..
Anyway, update the `.devx._stackscope`,
- log formatting to be a little more "sclangy" lookin.
- change the per-actor "delimiter" lines style.
- report the `signal.getsignal(SIGINT)` which i needed in the
`sync_bp.py` with ctl-c causing a hang..
- mask the `_tree_dumped` duplicator log report as well as the "dumped
fine" one.
- add an example `pkill --signal SIGUSR1` cmdline.
Tweak the test to cope with,
- not showing our script lines now.. which i've commented in the
`assert_before()` patts..
- to expect the newly formatted delimiter (ascii) lines to separate the
root vs. hanger sub-actor sections.
That is whenever `trio.EndOfChannel` is raised (presumably from the
`._to_trio.receive()` call inside `LinkedTaskChannel.receive()`) we need
to be extra certain that we let it bubble upward transparently DESPITE
special exc-as-signal handling that is normally suppressed from the aio
side; REPEAT we want to ALWAYS bubble any `trio_err ==
trio.EndOfChannel` in the `finally:` handler of `translate_aio_errors()`
despite `chan._trio_to_raise == AsyncioTaskExited` such that the
caller's iterable machinery will operate as normal when the inter-task
stream is stopped (again, presumably by the aio side task terminating
the inter-task stream).
Main impl deats for this,
- in the EoC handler block ensure we assign both `chan._trio_err` and
the local `trio_err` as well as continue to re-raise.
- add a case to the match block in the `finally:` handler which FOR SURE
re-raises any `type(trio_err) is EndOfChannel`!
Additionally fix a bad bug,
- a ref bug where we were NOT using the
`except BaseException as _trio_err` to assign to `chan._trio_err` (by
accident was missing the leading `_`..)
Unrelated impl tweak,
- move all `maybe_raise_aio_side_err()` content back to inline with its
parent func - makes it easier to use `tractor.pause()` mostly Bp
- go back to trying to use `aio_task.set_exception(aio_taskc)` for now
even though i'm pretty sure we're going to move to a try-fute-first
style helper for this in the future.
Adjust some tests to match/mk-them-green,
- break from `aio_echo_server()` recv loop on
`to_asyncio.TrioTaskExited` much like how you'd expect to (implicitly
with a `for`) with a `trio.EndOfChannel`.
- toss in a masked `value is None` pause point i needed for debugging
inf looping caused by not re-raising EoCs per the main patch
description.
- add a debug-mode sized delay to root-infected test.
Such that any combination of task terminations/exits can be explicitly
handled and "dual side independent" crash cases re-raised in egs.
The main error-or-exit impl changes include,
- use of new per-side "signaling exceptions":
- TrioTaskExited|TrioCancelled for signalling aio.
- AsyncioTaskExited|AsyncioCancelled for signalling trio.
- NOT overloading the `LinkedTaskChannel._trio/aio_err` fields for
err-as-signal relay and instead add a new pair of
`._trio/aio_to_raise` maybe-exc-attrs which allow each side's
task to specify what it would want the other side to raise to signal
its/a termination outcome:
- `._trio_to_raise: AsyncioTaskExited|AsyncioCancelled` to signal,
|_ the aio task having returned while the trio side was still reading
from the `asyncio.Queue` or is just not `.done()`.
|_ the aio task being self or trio-request cancelled where
a `asyncio.CancelledError` is raised and caught but NOT relayed
as is back to trio; instead signal a "more explicit" exc type.
- `._aio_to_raise: TrioTaskExited|TrioCancelled` to signal,
|_ the trio task having returned while the aio side was still reading
from the mem chan and indicating that the trio side might not
care any more about future streamed values (like the
`Stop/EndOfChannel` equivs for ipc `Context`s).
|_ when the trio task canceld we do
a `asyncio.Future.set_exception(TrioTaskExited())` to indicate
to the aio side verbosely that it should cancel due to the trio
parent.
- `_aio/trio_err` are now left to only capturing the **actual**
per-side task excs for introspection / other side's handling logic.
- supporting "graceful exits" depending on API in use from
`translate_aio_errors()` such that if either side exits but the other
side isn't expect to consume the final `return`ed value, we just exit
silently, which required:
- adding a `suppress_graceful_exits: bool` flag.
- adjusting the `maybe_raise_aio_side_err()` logic to use that flag
and suppress only on certain combos of `._trio_to_raise/._trio_err`.
- prefer to raise `._trio_to_raise` when the aio-side is the src and
vice versa.
- filling out pedantic logging for cancellation cases indicating which
side is the cause.
- add a `LinkedTaskChannel._aio_result` modelled after our
`Context._result` a a similar `.wait_for_result()` interface which
allows maybe accessing the aio task's final return value if desired
when using the `open_channel_from()` API.
- rename `cancel_trio()` done handler -> `signal_trio_when_done()`
Also some fairly major test suite updates,
- add a `delay: int` producing fixture which delivers a much larger
timeout whenever `debug_mode` is set so that the REPL can be used
without a surrounding cancel firing.
- add a new `test_aio_exits_early_relays_AsyncioTaskExited` including
a paired `exit_early: bool` flag to `push_from_aio_task()`.
- adjust `test_trio_closes_early_causes_aio_checkpoint_raise` to expect
a `to_asyncio.TrioTaskExited`.
It appears that during the reorg commit
a356233b47 this was intended to be moved
(presumably where i have here) to `test_tooling` but was somehow just
never pasted over XD
Good thing this was caught while going through the remaining TODO
bullets in #2 !!
Also includes fixed relative `.conftest` imports!